Dental Research Journal، جلد ۱۲، شماره ۲، صفحات ۰-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts
چکیده انگلیسی مقاله Background: Different factors such as impression techniques and materials can affect the passive fi t between the superstructure and implant. The aim of this study was to determine the effect of different impression materials and techniques on the dimensional accuracy of implant defi nitive casts. Materials and Methods: Four internal hex implants (Biohorizons Ø4 mm) were placed on a metal maxillary model perpendicular to the horizontal plane in maxillary lateral incisors, right canine and left fi rst premolar areas. Three impression techniques including open tray, closed tray using ball top screw abutments and closed tray using short impression copings and two impression materials (polyether and polyvinyl siloxane) were evaluated ( n = 60). The changes in distances between implant analogues in mediolateral (x) and anteroposterior (y) directions and analogue angles in x/z and y/z directions in the horizontal plane on the defi nitive casts were measured by coordinate measuring machine. The data were analyzed by multivariate two-way analysis of variance and one sample t -test (α = 0.05). Results: No statistical signifi cant differences were observed between different impression techniques and materials. However, deviation and distortion of defi nitive casts had a signifi cant difference with the master model when short impression copings and polyvinyl siloxane impression material were used ( P < 0.05). In open tray technique, there was a signifi cant difference in the rotation of analogs compared with the master model with both impression materials ( P < 0.05). Conclusion: There was no difference between open and closed tray impression techniques; however, less distortion and deviation were observed in the open tray technique. In the closed tray impression technique, ball top screw was more accurate than short impression copings. Key Words: Dental implants, dental impression materials, dental impression techniques, dental models
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله بهناز عبادیان | behnaz ebadian


منصور ریسمانچیان | mansor rismanchian


بدرالسادات دستغیب | badrosadat dastgheib


فرشاد باجغلی | farshad bajoghli



نشانی اینترنتی http://drj.mui.ac.ir/index.php/drj/article/view/1677
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات