این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 24 مهر 1404
Journal of Medical Signals and Sensors
، جلد ۱۴، شماره ۱۱، صفحات ۱۰-۴۱۰۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Dose Calculation Algorithms Accuracy for ISOgray Treatment Planning System in Motorized Wedged Treatment Fields
چکیده انگلیسی مقاله
Abstract Background: Different dose calculation methods vary in accuracy and speed. While most methods sacrifice precision for efficiency Monte Carlo (MC) simulation offers high accuracy but slower calculation. ISOgray treatment planning system (TPS) uses Clarkson, collapsed cone convolution (CCC), and fast Fourier transform (FFT) algorithms for dose distribution. This study’s primary goal is to evaluate the dose calculation accuracy for ISOgray TPS algorithms in the presence of a wedge. Methods: This study evaluates the dose calculation algorithms using the ISOgray TPS in the context of radiation therapy. The authors compare ISOgray TPS algorithms on an Elekta Compact LINAC through MC simulations. The study compares MC simulations for open and wedge fields with ISOgray algorithms by using gamma index analysis for validation. Results: The percentage depth dose results for all open and wedge fields showed a more than 98% pass rate for points. However, there were differences in the dose profile gamma index results. Open fields passed the gamma index analysis in the in-plane direction, but not all points passed in the cross-plane direction. Wedge fields passed in the cross-plane direction, but not all in the in-plane direction, except for the Clarkson algorithms. Conclusion: In all investigated algorithms, error increases in the penumbra areas, outside the field, and at cross-plane of open fields and in-plane direction of wedged fields. By increasing the wedge angle, the discrepancy between the TPS algorithms and MC simulations becomes more pronounced. This discrepancy is attributed to the increased presence of scattered photons and the variation in the delivered dose within the wedge field, consequently impacts the beam quality. While the CCC and FFT algorithms had better accuracy, the Clarkson algorithm, particularly at larger effective wedge angles, exhibited greater effectiveness than the two mentioned algorithms.
کلیدواژههای انگلیسی مقاله
Dose calculation algorithms,effective wedge angle,GATE,ISOgray,Monte Carlo simulation,treatment planning system
نویسندگان مقاله
| Sajjad Raghavi
Department of Medical Physics and Radiology, Faculty of Paramedicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
| Hamid-Reza Sadoughi
1.Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran 3.Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
| Mohammad Ehsan Ravari
1.Department of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran 3.Cancer Research Center, Semnan University of Medical Sciences, Semnan, Iran
| Marziyeh Behmadi
نشانی اینترنتی
http://jmss.mui.ac.ir/index.php/jmss/article/view/733
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Articles
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات