|
International Journal of Radiation Research، جلد ۲۳، شماره ۲، صفحات ۳۰۵-۳۰۹
|
|
|
عنوان فارسی |
|
|
چکیده فارسی مقاله |
|
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
Image Quality and Radiation Dose of Portal Venous Imaging by Dual-Source Computed Tomography Single Energy Technology |
|
چکیده انگلیسی مقاله |
Background: The design of this work was to explore the feasibility of optimizing computed tomography (CT) portal vein image quality and radiation dose by virtual single-energy imaging technology. Materials and Methods: Nighty-two patients who underwent dual-source CT (DSCT) examination in our hospital from September 2021 and August 2022 were selected as the study objects. They received CT scanning (90/Sn150 kV) and the images of 40 keV to 100 keV and M_0.6 linear fusion were obtained. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and radiation dose of different models were calculated. Results: Statistical significance in the subjective score of image quality was tested among all groups, and the 40 keV group had the highest score. The SD values in 40 keV to 60 keV were elevated, while were declined in 80 keV to 100 keV compared with the M_0.6 fusion image. CNR values in 40 keV to 70 keV groups were significantly higher, and in 90 keV to 100 keV were lower than those in M_0.6 group. SNR in the 40 keV group was significantly better than that in M_0.6 group. The average radiation doses were 6.12 ± 1.30 CTDIvol (mGy) and the radiation dose length product (DLP) was 304.3 ± 87.67 (mGy.cm). Conclusion: DSCT virtual single energy reconstruction technology could greatly improve image quality, and 40 keV single energy reconstruction had the best image quality. |
|
کلیدواژههای انگلیسی مقاله |
Computed tomography, radiographic image enhancement, portal vein, radiation dosage, signal-to-noise ratio. |
|
نویسندگان مقاله |
| Z. Liang Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
| Z. Liang Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
| Y. Duan Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
| W. Liu Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
| Z. Han Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
| R. Wang Department Radiology Department, Beijing Shijitan Hospital, Beijing 100038, China
|
|
نشانی اینترنتی |
http://ijrr.com/browse.php?a_code=A-10-1-1329&slc_lang=en&sid=1 |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
|
زبان مقاله منتشر شده |
en |
موضوعات مقاله منتشر شده |
Radiation Biology |
نوع مقاله منتشر شده |
تحقیق بدیع |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|