The Effect of Lubricant on the Detorque Force of Locator/Kerator Abutment in Overdenture Patients: A Pilot Clinical Study
چکیده انگلیسی مقاله
Background:
Despite the implants' remarkable success, mechanical failure of implant-abutment screws is a challenge for clinicians. Among the types of mechanical failures, abutment screw loosening is still frequently reported in the literature
Purpose:
The present study aimed to evaluate the effect of using lubricant on the detorque force (removal force) of locator/kerator abutment in overdenture patients after 6 months of clinical usage.
Materials and Method:
This pilot clinical study examined the detorque force of implants in 20 edentulous patients with two mandibular implants positioned between the mental foramen. The patients underwent the fabrication of a complete maxillary prosthesis and mandibular overdenture. Before loading attachments in the delivery session, healing abutments were removed, and implant interiors dried, randomly some fixtures received a tetracycline eye ointment 1% lubricant, while the others remained non-lubricated. Abutments were secured with prescribed torque according to implant system guidelines (20 N.cm). After 6 months, detorque forces for the abutment locators were measured using a torque meter. Descriptive statistics, mean comparison, and Pearson correlation were performed on the obtained data. A significant level of P<0.05 was considered in the present study.
Results
: The mean detorque force was 13.4±1.94 in the non-lubricated group and 16.35± 1.24 in the lubricated group, which was significantly higher in the lubricated group (
p
< 0.001). Other results of the study include the non-significance of the difference in detorque force within male and female groups (
p
> 0.05), as well as the non-significance of Pearson's correlation between patients' age and detorque force (
p
> 0.05).
Conclusion:
According to the results, the use of lubricant significantly increases the detorque force, and it is recommended to use tetracycline eye ointment as a lubricant in implant treatment processes.
کلیدواژههای انگلیسی مقاله
Dental Implantation,Dental Abutments,Lubricants,Torque
نویسندگان مقاله
Ali Chamani |
Postgraduate Student, Dept. of Endodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
ِِDavood Aghasizadeh |
Dept. of Prosthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
Hamidreza Rajati Haghi |
Dept. of Prosthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
Ghazal Aghebati |
Student Research Committee, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
Reza Shakiba |
Student Research Committee, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
نشانی اینترنتی
https://dentjods.sums.ac.ir/article_50376_95cb2cf9e631e69f1425bfd129c7c3fa.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات