این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 30 آبان 1404
گوارش
، جلد ۲۹، شماره ۴، صفحات ۲۲۶-۲۳۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparative Evaluation of Fibrosis-4 Index and FibroScan for Liver Fibrosis Estimation among Psoriatic Arthritis Patients on Methotrexate
چکیده انگلیسی مقاله
Background: Psoriatic arthritis (PsA) often requires long-term methotrexate (MTX) therapy, which is associated with the risk of liver fibrosis. Non-invasive tests like elastography and the Fibrosis-4 (FIB-4) index have been studied to assess liver stiffness. This study aimed to compare the FIB-4 index with liver fibrosis severity measured by FibroScan in PsA patients on MTX. Materials and Methods: A cross-sectional study included patients with PsA on MTX at the Rheumatology Clinic of Hazrat Rasoul Akram Hospital. Data were collected on demographics, clinical characteristics, FIB-4 index, and liver stiffness measured by FibroScan. Statistical analyses evaluated correlations between FIB-4 and FibroScan results. Results: Among 70 participants, 21 (30%) were men. The mean ( + standard deviation [SD]) age of all study subjects was 55.11 (±15.15) years. The average ( + SD) disease duration was 7.34 (±5.18) years. The mean ( + SD) FIB-4 index was 1.19 (±0.64). A total of 53 (75.71%), 15 (21.43%), and 2 (2.86%) study subjects according to FIB-4 index, and 56 (80%), 8 (11.43%), and 6 (8.57%) according to Fibroscan grades were categorized as having ‘normal to mild’, ‘mild to moderate’, and ‘moderate to severe’ liver fibrosis, respectively. There was a weak positive but non-significant correlation between FIB-4 and FibroScan scores (r=0.01; P=0.936). A normal to mild FIB-4 index correctly excluded moderate to severe fibrosis in 51% of cases, which was not statistically significant (P=0.504). Conclusion: The FIB-4 index showed a limited correlation with liver fibrosis severity measured by FibroScan in patients with PsA on MTX therapy. While FIB-4 may be a potential screening tool, it is not sufficiently accurate to replace elastography. Further studies with larger samples are required.
کلیدواژههای انگلیسی مقاله
Psoriatic arthritis, Methotrexate, Liver fibrosis, FIB-4 index, FibroScan, Elastography
نویسندگان مقاله
| Nahid Kianmehr
Rheumatology Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Parnasadat Hosseini-Migoni
Rheumatology Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Anousheh Haghighi
Rheumatology Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Marjan Rajab Taraghi
Rheumatology Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Pegah Shahbazian
Rheumatology Department, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| Majid Salmanian
Gastrointestinal and Liver Diseases Research Center, Iran University of Medical Sciences, Tehran, Iran
| Morteza Hassanzadeh
نشانی اینترنتی
http://govaresh.org/index.php/dd/article/view/2732
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات