این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 3 خرداد 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۲۵، شماره ۳، صفحات ۲۰۳-۲۱۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparative Evaluation of the Accuracy of Electronic Apex Locator and Digital Radiography for Working Length Determination in Primary Teeth: A Systematic Review
چکیده انگلیسی مقاله
Statement of the Problem:
It is challenging to perform a pulpectomy procedure in primary tooth because of its physiological root resorption and variation in root morphology. Working length measurement is considered to be one of the critical steps, as it determines the extent of obturation and apical seal.
Purpose:
To compare the accuracy of electronic apex locator (EAL) and digital radiography (DR) for working length determination in primary teeth.
Materials and Method:
In this systematic review, electronic databases and grey literature were searched from 1st January 2005 to 1
st
January 2023 for randomized control trial, non- randomized control trial,
in vitro
studies,
ex vivo
studies that compared accuracy of EAL and DR in primary teeth. Two reviewers independently identified studies, retrieved data, and assessed risk of bias using the revised and validated MINORS (methodological index for non-randomized studies) criteria.
Results:
Ten studies were included in qualitative analysis. Seven out of ten studies showed low risk of bias whereas other three studies showed high risk of bias. In view of methodological heterogeneity of the findings, a meta-analysis was not conducted.
Conclusion:
Available evidence suggests a moderate quality of evidence in this systematic review. Analyzing the ten studies included in this systematic review, the majority of studies showed statistically insignificant difference between EAL and DR. However, EAL was closer to actual WL as compared to DR. Based on the evidence that is currently available; EAL can be considered as an alternative for working length measurement in primary teeth.
کلیدواژههای انگلیسی مقاله
Dental Radiovisiography,Digital Dental Radiography,Primary Dentitions,Milk Tooth
نویسندگان مقاله
Ishita Agrawal |
Postgraduate Student, Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, India.
Farhin Katge |
Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, Maharashtra, India.
Sanmati Pol |
Lecturer, Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, Maharashtra, India.
Devendra Patil |
Lecturer, Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, Maharashtra, India.
Vamsi Krishna Chimata |
Reader, Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, Maharashtra, India.
Debapriya Pradhan |
Dept. of Pediatric and Preventive Dentistry, Terna Dental College, Sector-22, Nerul West, Navi-Mumbai, Maharashtra, India.
نشانی اینترنتی
https://dentjods.sums.ac.ir/article_49428_5758ada007bfa987ad3755bc20c80708.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات