|
Journal of Dentistry, Tehran University of Medical Sciences، جلد ۱۳، شماره ۵، صفحات ۳۳۳-۳۳۹
|
|
|
عنوان فارسی |
|
|
چکیده فارسی مقاله |
|
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
Accuracy of Linear Measurements Using Cone Beam Computed Tomography in Comparison with Clinical Measurements |
|
چکیده انگلیسی مقاله |
Objectives: This study sought to evaluate the accuracy and errors of linear measurements of mesiodistal dimensions of Kennedy Class III edentulous space using cone beam computed tomography (CBCT) in comparison with clinical measurements. Materials and Methods: Nineteen Kennedy Class III dental arches were evaluated. An impression was made of each dental arch and poured with dental stone. The distance was measured on dental cast using a digital Vernier caliper with an accuracy of 0.1mm and on CBCT scans. Finally, the linear mesiodistal measurements were compared and the accuracy of CBCT technique was evaluated by calculating absolute value of errors, intra-class correlation coefficient and simple linear regression model. Results: In comparison with the cast method, estimation of size on CBCT scans had an error of -8.46% (underestimation) to 5.21% (overestimation). In 26.5% of the cases, an accepted error of ±1% was found. The absolute value of errors was found to be in the range of 0.21-8.46mm with an average value of 2.86 ±2.30mm. Conclusions: Although the measurements revealed statistically significant differences, this does not indicate a lower accuracy for the CBCT technique. In fact, CBCT can provide some information as a paraclinical tool and the clinician can combine these data with clinical data and achieve greater accuracy. Undoubtedly, calibration of data collected by clinical and paraclinical techniques and the clinician’s expertise in use of CBCT software programs can increase the accuracy of implant placement. |
|
کلیدواژههای انگلیسی مقاله |
|
|
نویسندگان مقاله |
امیر رضا رکن رکن | amir reza rokn rokn
کاظم هاشمی | kazem hashemi
سولماز اکبری | solmaz akbari
محمد جواد خرازی فرد | mohammad javad kharazifard
حمیدرضا باریکانی | hamidreza barikani
مهرداد پنج نوش | mehrdad panjnoosh
|
|
نشانی اینترنتی |
http://jdt.tums.ac.ir/index.php/jdt/article/view/1652 |
فایل مقاله |
اشکال در دسترسی به فایل - ./files/site1/rds_journals/61/article-61-314599.pdf |
کد مقاله (doi) |
|
زبان مقاله منتشر شده |
en |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
Original Article(s) |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|