این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 2 شهریور 1405
Journal of Applied Fluid Mechanics
، جلد ۱۰، شماره ۳، صفحات ۸۰۱-۸۱۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Experimental and Numerical Investigation on Laminar Pipe Flow of Magneto-Rheological Fluids under Applied External Magnetic Field
چکیده انگلیسی مقاله
An experimental and numerical study of Magnetorheological (MR) fluids flow in circular pipes under the influence of uniform magnetic field is considered. In the experiments, an electromagnetic device was manufactured to generate the magnetic field. The experiments were performed using magnetic fields B= 0, 0.01, 0.02, 0.03, 0.04, 0.05, 0.06, 0.07, 0.08, 0.09, 0.1, 0.12 and 0.15 T. Numerical study was performed to show the accuracy of the results obtained from experimental study. In numerical study, Computational Fluid Dynamics (CFD) analysis was used. The ANSYS Fluent 14.0 code based on the finite volume method was used for the CFD analysis. In the experiments, the applied magnetic field decreased the flow rate of the fluids by increasing viscosity. In case of 10 mm pipe diameter, the flow velocity of the A, B and C fluids were obtained as 0.593, 0.749 and 0.938 m/s respectively in situation B=0 T. When magnetic field was applied as B=0.15 T, decreases have occurred in the velocity of A, B and C fluids as 95.27%, 90.24% and 85.6% respectively. Similarly, in case of 15 mm pipe diameter, 96.87%, 95.06% and 90.76% decreases have occurred in the flow velocity of A, B and C fluids having 0.301, 0.363 and 0.445 m/s flow velocity respectively. The results were compared for the magnetic field values B=0, 0.05, 0.10 and 0.15 T. It was found that the differences between experimental and numerical study were found as 6.10% and 1.71% for the B=0 T and B≠0 T situations respectively when the pipe has 10 mm pipe diameter. In case of 15 mm pipe diameter, the differences were found as 2.31% and 0.89%. As a result, it was found that the results obtained from experimental and numerical study were qualitatively and quantitatively in good agreement.
کلیدواژههای انگلیسی مقاله
Magnetorheological (MR) fluid, Laminar pipe flow, Magnetic field, CFD
نویسندگان مقاله
E. Gedik |
Faculty of Technology, Karabük University, Karabük, TR-78050, Turkey
نشانی اینترنتی
https://www.jafmonline.net/article_477_63757f6f8f8e72ff5f76491f1622fc4f.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات