عنوان انگلیسی Tradeoffs between Radiation Exposure to the Lens of the Eyes and Diagnostic Image Quality in Pediatric Brain Computed Tomography
چکیده انگلیسی مقاله Background: Computed tomography (CT) of the brain is associated with radiation exposure to the lens of the eyes. Therefore, it is necessary to optimize scan settings to keep radiation exposure as low as reasonably achievable without compromising diagnostic image information. The aim of this study was to compare the effectiveness of the five practical techniques for lowering eye radiation exposure and their effects on diagnostic image quality in pediatric brain CT. Methods: The following scan protocols were performed: reference scan, 0.06?mm Pbeq bismuth shield, 30% globally lowering tube current (GLTC), reducing tube voltage (RTV) from 120 to 90 kVp, gantry tilting, and combination of gantry tilting with bismuth shielding. Radiation measurements were performed using thermoluminescence dosimeters. Objective and subjective image quality was evaluated. Results: All strategies significantly reduced eye dose, and increased the posterior fossa artifact index and the temporal lobe artifact index, relative to the reference scan. GLTC and RTV increased image noise, leading to a decrease signal?to?noise ratio and contrast?to?noise ratio. Except for bismuth shielding, subjective image quality was relatively the same as the reference scan. Conclusions: Gantry tilting may be the most effective method for reducing eye radiation exposure in pediatric brain CT. When the scanner does not support gantry tilting, GLTC might be an alternative
کلیدواژه‌های انگلیسی مقاله Brain computed tomography, eye lens, image quality, radiation exposure

نویسندگان مقاله | Vahid Karami
Department of Biomedical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran


| Mohsen Albosof
Department of Medical Physics, Lorestan University of Medical Sciences, Khorramabad, Iran


| Mehrdad Gholami
Department of Biomedical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran


| Mohammad Adeli
Department of Radiology, Isfahan University of Medical Sciences, Isfahan, Iran


| Ali Hekmatnia
Vahid Karami, Clinical Research Development Unit, Ganjavian Hospital, Dezful University of Medical Sciences, Dezful, Iran.


| Mehdi Fallah
Clinical Research Development Unit, Ganjavian Hospital, Dezful University of Medical Sciences, Dezful, Iran


| Bagher Sheidaei
Department of Biomedical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran


| Ali Taghizadeh Behbahani
Clinical Research Development Unit, Ganjavian Hospital, Dezful University of Medical Sciences, Dezful, Iran


| Hoda Sadat Sharif
Clinical Research Development Unit, Ganjavian Hospital, Dezful University of Medical Sciences, Dezful, Iran,


| Somayeh Jafrasteh



نشانی اینترنتی http://jmss.mui.ac.ir/index.php/jmss/article/view/677
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Articles
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات