این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 22 خرداد 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۲۴، شماره ۲، صفحات ۱۶۸-۱۸۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Two Pain Assessment Methods (Tactile and air Blast) for Comparison the Effectiveness of Nd:YAG Laser Therapy and Non-Laser Therapy on Dentin Hyper Sensitivity Treatment: a systematic Review and Meta-analysis
چکیده انگلیسی مقاله
Statement of the Problem: Dentin hypersensitivity (DH) is a common irritating condition. A precise sensitive test for its assessment can greatly aid in appropriate treatment planning.Purpose: This meta-analysis aims to compare the air blast and tactile tests for assessment of the efficacy Nd:YAG laser therapy versus non-laser treatments for DH in short-term and long-term follow-ups.Materials and Method: for this review, an electronic search of the literature was carried out in three databases by two researchers for English articles published until March 10, 2021. Pooling of the data extracted from the selected articles was performed according to the PRISMA statement by the random-effect model. The mean difference (MD) and 95% confidence interval (CI) of pain score before the treatment onset and during the follow-up period according to the visual analog scale (VAS) were calculated. The level of heterogeneity was assessed by the I2 test, and a funnel plot was drawn to assess the publication bias of the reviewed studies.Results: Of 152 articles primarily retrieved, 9 randomized clinical trials (RCTs) using the air blast test and 4 RCTs using the tactile test were subjected to quantitative synthesis. In the short-term follow-up and immediately after treatment, the air blast test showed superiority of laser therapy compared with non-laser treatments (SMD: 0.55, 95% CI: 0.05-1.04, p= 0.03). However, this difference was not significant according to the tactile test (SMD: 0.48. 95% CI: 0.01-0.96, p= 0.06). In the long-term follow-up, the difference between laser therapy and non-laser modalities was not significant according to both air blast (SMD= -0.38, 95% CI: -1.43-0.67, p= 0.48) and tactile (SMD=0.0, 95% CI: -0.38-0.38, p= 0.99) tests.Conclusion: Comparison of laser therapy and non-laser modalities in the short-term revealed higher sensitivity of the air blast test due to its mechanism of action compared with the tactile test. Further studies are required to interpret the results in the long-term follow-up.
کلیدواژههای انگلیسی مقاله
Dentin Hypersensitivity, Nd YAG Laser, Topical Desensitizing Agent, Air Blast Test, Tactile Test, Meta-analysis
نویسندگان مقاله
Zahra Baghani |
Dept. of Periodontics, Faculty of Dentistry, Sabzevar University of Medical Sciences, Sabzevar, Iran.
Malihe Karrabi |
Dept. of Prosthodotics, Faculty of Dentistry Sabzevar University of Medical Sciences, Sabzevar, Iran.
نشانی اینترنتی
https://dentjods.sums.ac.ir/article_48858_1e14e2aba10d3118562d2ee0d827c3ed.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات