Evaluation of Ultra-Low-Dose Chest Computed Tomography Images in Detecting Lung Lesions Related to COVID-19: A Prospective Study
چکیده انگلیسی مقاله
Background: The present study aimed to evaluate the effectiveness of ultra-low-dose (ULD) chest computed tomography (CT) in comparison with the routine dose (RD) CT images in detecting lung lesions related to COVID-19.Methods: A prospective study was conducted during April-September 2020 at Shahid Faghihi Hospital affiliated with Shiraz University of Medical Sciences, Shiraz, Iran. In total, 273 volunteers with suspected COVID-19 participated in the study and successively underwent RD-CT and ULD-CT chest scans. Two expert radiologists qualitatively evaluated the images. Dose assessment was performed by determining volume CT dose index, dose length product, and size-specific dose estimate. Data analysis was performed using a ranking test and kappa coefficient (κ). P< 0.05 was considered statistically significant.Results: Lung lesions could be detected with both RD-CT and ULD-CT images in patients with suspected or confirmed COVID-19 (κ=1.0, P=0.016). The estimated effective dose for the RD-CT protocol was 22-fold higher than in the ULD-CT protocol. In the case of the ULD-CT protocol, sensitivity, specificity, accuracy, and positive predictive value for the detection of consolidation were 60%, 83%, 80%, and 20%, respectively. Comparably, in the case of RD-CT, these percentages for the detection of ground-glass opacity (GGO) were 62%, 66%, 66%, and 18%, respectively. Assuming the result of real-time polymerase chain reaction as true-positive, analysis of the receiver-operating characteristic curve for GGO detected using the ULD-CT protocol showed a maximum area under the curve of 0.78. Conclusion: ULD-CT, with 94% dose reduction, can be an alternative to RD-CT to detect lung lesions for COVID-19 diagnosis and follow-up.
کلیدواژههای انگلیسی مقاله
COVID-19, Radiation protection, Computed Tomography
نویسندگان مقاله
Fariba Zarei |
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Reza Jalli |
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Sabyasachi Chatterjee |
Ongil, 79 D3, Sivaya Nagar, Reddiyur Alagapuram, Salem, India
Rezvan Ravanfar Haghighi |
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Pooya Iranpour |
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
Vani Vardhan Chatterjee |
Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
Sedigheh Emadi |
Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
نشانی اینترنتی
https://ijms.sums.ac.ir/article_48291_3ea841d24be48728f71b080fe286a379.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات