این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 3 مرداد 1405
Iranian Endodontic Journal
، جلد ۱۵، شماره ۱، صفحات ۳۸-۴۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Apical Debris Extrusion with Conventional Rotary and Reciprocating Instruments
چکیده انگلیسی مقاله
Introduction: The aim of the present study was to compare the amount of apical debris extrusion after preparation using hand files, reciprocating files, and full rotary nickel-titanium systems. Methods and Materials: One hundred extracted human mandibular molars with two separated canals in mesial root were divided into five groups and prepared using reciprocating systems (Reciproc and Safesider endodontic reamer files), full rotary systems (Mtwo and Neoniti A1 files) and hand instrumentation systems. Endodontic access was prepared and a #15 K-file was passed beyond the apex of the mesiobuccal canal by 1 mm to ensure the canal patency. All mesiobuccal canals were prepared 1 mm shorter than the anatomic apex. In each case, extruded debris was collected in an Eppendorf tube and weighed after desiccation. The mean weight of extruded material was calculated in each group. The analysis was carried out using the Kruskal–Wallis test followed by two tailed and Mann-Whitney U test at a significance level of 0.05. The Bonferroni correction was also applied to correct multiple comparisons. Results: There was a statistically significant difference between the reciprocal and other techniques in debris extrusion ( P < 0.05). The order of groups ranked in terms of debris extrusion from the lowest to highest was as follows: 1) Hand instrumentation group (with crown down technique), 2) Mtwo group, 3) Neoniti A1 group, 4) Safesider endodontic reamer group, and 5) Reciproc group. Conclusion: Based on this in vitro study, all systems have some apical debris extrusion; however, using the hand instrumentation system resulted in extrusion of significantly less debris compared to the Reciproc group. It seems that hand and rotary instrumentation systems are better than reciprocating instrumentation systems in terms of the amount of debris extrusion.
کلیدواژههای انگلیسی مقاله
Endodontics, Root Canal Preparation, Rotary Instrumentation
نویسندگان مقاله
| Eshagh Ali Saberi
Associatet Professor, Dep of Endodontics, School of Dentistry and Dental Research Center of Birjand University of Medical Sciences
| Sediqe Ebrahimipour
| Mersad Saberi
نشانی اینترنتی
http://journals.sbmu.ac.ir/iej/article/view/23823
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/109/article-109-2206590.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات