این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 30 آبان 1404
International Journal of Engineering
، جلد ۳۰، شماره ۱۰، صفحات ۱۴۶۴-۱۴۷۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
The Effect of Caspian Sea Water on Corrosion Resistance and Compressive Strength of Reinforced Concrete Containing Different SiO2 Pozzolan
چکیده انگلیسی مقاله
Many parameters are influenced by the diffusion of chloride on concrete in marine environments and these can affect concrete quality. In this study, the effect of water to cement ratio of 0.35, 0.40 and 0.45 on corrosion resistance and compressive strength of reinforced concrete was evaluated. Moreover, different percentages of micro silica (SiO2) including 5, 7.5 and 10% were utilized, in order to investigate the effect of pozzolanic materials on the corrosion of steel in concrete. Then cubic samples reinforced with steel bar spacing of 2.5, 5 and 7 cm from the cube surface were made and put in Caspian sea water for 5 months. During this period, corrosion potential of steel was measured by a calomel half cell (SCE). In order to finalize the evaluation of the mechanical strength of the samples, concrete pressure test was conducted and the result showed that after 40, 44 and 59 days for the bars with depth of 2.5, 5 and 7 cm, respectively and the samples prepared with water-cement ratio of 0.35, the corrosion potential was -350V versus SCE, while the compressive strength was approximately 450 kg/cm2. This result showed longer life span of this sample in comparison with other water-cement ratios. By adding micro silica to the samples up to 7.5%, the time for obtaining a corrosion potential of -350V, bars with depth of 2.5, 5 and 7 cm, was 43, 50 and 86 days, respectively, and the compressive strength of this sample was approximately 480 kg/cm2. Consequently, it is arguable that in order to achieve longer life span of corrosion and suitable compressive strength, the optimum ratio of water to cement should be 0.35 and the percentage of pozzolan SiO2 should be 7.5%.
کلیدواژههای انگلیسی مقاله
Chloride, Corrosion Potential, Steel Corrosion, Micro Silica
نویسندگان مقاله
Seyed Rahim Kiahosseini |
Department of Engineering,, Damghan Branch, Islamic Azad University
Shaban Borzouyi Kutenayi |
Iranian Space Agency, Engineering Research Institute, Isfahan Engineerin
Mohammad Hosein Talebpour |
Department of Engineering, Damghan Branch, Islamic Azad University, Damghan,
نشانی اینترنتی
http://www.ije.ir/article_73027_ac6a1cc912dd359e5734138938197782.pdf
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/409/article-409-2061994.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات