International Journal of Engineering، جلد ۳۲، شماره ۷، صفحات ۱۰۳۱-۱۰۳۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Experimental and Numerical Investigation of Air Temperature Distribution inside a Car under Solar Load Condition
چکیده انگلیسی مقاله In this work both experimental and numerical analysis are carried out to investigate the effect of solar radiation on the cabin air temperature of Maruti Suzuki Celerio car parked for 90 min under solar load condition. The experimental and numerical analysis encompasses on temperature increment of air at various locations inside the vehicle cabin. The effect of 90 min exposure to the environment is simulated with the help of Discrete Ordinance (DO) and Surface to Surface (S2S) radiation models using ANSYS FLUENT 18.2. Moreover, the impacts of using different turbulence model on the accuracy of the simulation results and the comparison between steady state and transient state simulation results have also been studied. The results of the simulation are compared with the experimental data to contrast the model. The absolute average deviation in temperature predicted by DO and S2S model from the experimental data are 10.07 and 10.01%, respectively. In this work both experimental and numerical analysis are carried out to investigate the effect of solar radiation on the cabin air temperature of Maruti Suzuki Celerio car parked for 90 min under solar load condition. The experimental and numerical analysis encompasses on temperature increment of air at various locations inside the vehicle cabin. The effect of 90 min exposure to the environment is simulated with the help of Discrete Ordinance (DO) and Surface to Surface (S2S) radiation models using ANSYS FLUENT 18.2. Moreover, the impacts of using different turbulence model on the accuracy of the simulation results and the comparison between steady state and transient state simulation results have also been studied. The results of the simulation are compared with the experimental data to contrast the model. The absolute average deviation in temperature predicted by DO and S2S model from the experimental data are 10.07 and 10.01%, respectively.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله B. Srusti |
School of Mechanical and Building Sciences, VIT Chennai, India

M. B. Shyam Kumar |
School of Mechanical and Building Sciences, VIT Chennai, India


نشانی اینترنتی http://www.ije.ir/article_91337_841a013e5fd9b5bd001b603aea0ebdc9.pdf
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/409/article-409-2061568.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات