International Journal of Radiation Research، جلد ۲، شماره ۴، صفحات ۱۷۵-۱۸۳
|
|
|
عنوان فارسی |
|
|
چکیده فارسی مقاله |
|
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
The physical characteristics of a SLIC-EPID for transmitted dosimetry |
|
چکیده انگلیسی مقاله |
ABSTRACT Background: for treatment verification in radiation therapy. Several physical characteristics of ScanningLiquid filled Ionization Chamber EPID (SLIC-EPID) including: extra build-up layer,reproducibility and uniformity, and noise level were investigated.Electronic Portal Imaging Devices (EPIDs) have found an outstanding positionMaterials and Methods: equilibrium, 1-30 mm white water materials (RW3) were placed on the EPID cover and thevariation of pixel values were investigated. To assess the short term reproducibility, a series of10 consecutive Electronic Portal Images (EPIs) were acquired. The variation of pixel valueswere then determined in irradiated field using MATLAB software. For long term reproducibility,the described above experiment was then repeated seven times. To determine the noise levelin EPID images, 10 consecutive flood images were acquired. The measurement was repeatedafter two days during a fortnight.To determine the extra build-up layer to reach the electronicResults: No significant variation was observed between the maximum thickness of build-up layerrequired for the central axis and peripheral points. For reproducibility measurements, no systematicvariation was observed between mean, maximum and minimum acquired pixel values.Both the long-term and short term reproducibility was found to be less than 1%. The noise levelwas generally less than 1% and this can be referred as an acceptable dose level5 mm of RW3 material was found to increase the pixel values to the maximum possible..Conclusion:can be used for dosimetry. However, for a particular linac energy and EPID image acquisitionmode, the extra build-up layer thickness must be known for the EPID to be used for dosimetricpurposesThe physical characteristics, measured in this work, suggest that the SLIC-EPID. Iran. J. Radiat. Res., 2005 2 (4): 175-183 |
|
کلیدواژههای انگلیسی مقاله |
|
|
نویسندگان مقاله |
محمدی | m mohammadi department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia
e bezak | e bezak department of medical physics, royal adelaide hospital. adelaide, sa 5000, australia
|
|
نشانی اینترنتی |
http://www.ijrr.com/browse.php?a_code=A-10-1-83&slc_lang=en&sid=en |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
|
زبان مقاله منتشر شده |
en |
موضوعات مقاله منتشر شده |
Radiation Biology |
نوع مقاله منتشر شده |
تحقیق بدیع |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|