|
International Journal of Radiation Research، جلد ۱۴، شماره ۱، صفحات ۷۳-۷۶
|
|
|
عنوان فارسی |
|
|
چکیده فارسی مقاله |
|
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
Response of TLD and RPL personal dosimeters in a national inter-comparison test program |
|
چکیده انگلیسی مقاله |
Background: Different kinds and models of personal dosimeters are used in individual monitoring by workers. Performance testing as part of approval procedures is carried out to demonstrate that the essential performance specifications are routinely maintained. There are four service providers in Iran which use different luminescence techniques (i. e. TLD and RPL) with various kinds of dosimeter materials/reader instruments in personal dosimetry services. Materials and Methods: A national performance approval tests program was performed for the dosimeters of the service providers in energy range of soft, 660 keV and 1.25 MeV, at the doses values around the recoding, investigation and annual dose limits, and different angle of incidents (e. g. 0, 20, 40 and 60 degree). Results: The results of this testing satisfies the overall accuracy criteria with 95% confidence levels specified by the ICRP, except that of RPL technique in low energy which overestimates the dose out of the acceptable accuracy band defined as the ICRP trumpet curves. Conclusion: The inter-comparison has proved that the personal dose equivalent quantity, Hp(10), defined by the ICRU and recommended by the IAEA are becoming widely accepted and implemented in most participated laboratories. |
|
کلیدواژههای انگلیسی مقاله |
|
|
نویسندگان مقاله |
n نواب مقدم | n navab moghadam faculty of energy engineering and physics, amirkabir university of technology, tehran, iran
سازمان اصلی تایید شده: دانشگاه صنعتی امیرکبیر (Amirkabir university of technology)
سید محمد حسینی پویا | s m hosseini pooya nuclear safety and radiological protection research department, nuclear science and technology research institute, tehran, iran
h آفریده | h. afarideh faculty of energy engineering and physics, amirkabir university of technology, tehran, iran
سازمان اصلی تایید شده: دانشگاه صنعتی امیرکبیر (Amirkabir university of technology)
محمدرضا کاردان | m r kardan nuclear safety and radiological protection research department, nuclear science and technology research institute, tehran, iran
|
|
نشانی اینترنتی |
http://www.ijrr.com/browse.php?a_code=A-10-1-601&slc_lang=en&sid=en |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
|
زبان مقاله منتشر شده |
en |
موضوعات مقاله منتشر شده |
Radiation Biology |
نوع مقاله منتشر شده |
مرور و بررسی کلی |
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|