این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 3 خرداد 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۲۰، شماره ۳، صفحات ۲۰۳-۲۰۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Assessment of the Capability of Bone Density Contrast Dissociation in Cone Beam Computed Tomography Compared to Digital Periapical Radiography by Using a Phantom
چکیده انگلیسی مقاله
Statement of the Problem: Assessment of bone density changes plays an important role in diagnosis, treatment, and follow-up procedures. The feasibility of cone-beam computed tomography (CBCT) for assessment of bone density changes is still controversial. Purpose: The aim of this study was to investigate the capability of bone density contrast dissociation of CBCT compared to digital periapical radiography. Materials and Method: In this in vitro, experimental study, we designed radiographic phantom for bone density simulation. The phantom was a polytetrafluoroethylene rectangular cube with five-chambers. Five micro-tubes (2 mL) containing different concentrations of dipotassium phosphate (K2HPO4) were placed within these chambers. Different concentrations of K2HPO4 were scanned by CBCT; the mean voxel value of each micro-tube was measured and compared with the concentration of K2HPO4 that represented bone density. Results: CBCT results showed that there were no significant correlations between 300 mg/mL and lower concentrations of K2HPO4 and CBCT voxel values (P≤0.52) but there was a significant correlation between concentrations of K2HPO4 higher than 300 mg/mL and CBCT voxel values (p< 0.001). Conclusion: CBCT is a reliable method for the assessment of bone density changes in the high range of bone density but it is not reliable for such assessment in the lower range of bone density. Digital periapical imaging method may not be applied for the assessment of bone density, whereas in higher densities, the employment of CBCT seems to be feasible.
کلیدواژههای انگلیسی مقاله
CBCT ● Intraoral digital radiography ● Bone density
نویسندگان مقاله
Zahra Ghoncheh |
Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, International Campus, Tehran, Iran.
Hanieh Kaviani |
Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, International Campus, Tehran, Iran.
Hosein Ghadiri Harvani |
Dept. of Medical Physics and Biomedical Engineering, and Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran.
Daryoush Goodarzipour |
Dept. of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, International Campus, Tehran, Iran.
Ahmad Reza Shamshiri |
Research Center for Caries Prevention, Dentistry Research Institute, Department of Community Oral Health, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
Paria Shams |
School of Dentistry, Tehran University of Medical Sciences, International Campus, Tehran, Iran.
نشانی اینترنتی
http://dentjods.sums.ac.ir/article_44915_e69b9be016cd42ba06413d233f925593.pdf
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/331/article-331-1854111.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات