این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 22 شهریور 1405
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۶۳-۳۶۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Study the effect of source to diaphragm distance (SDD) on beam penumbra width of Gamma Knife machine model 4C using Monte Carlo simulation
چکیده انگلیسی مقاله
Introduction: Stereotactic radiosurgery (SRS) is one of the conformal radiotherapy methods and Gamma Knife is a non-invasive SRS technique to treat intracranial lesions with 201 Co- 60 sources without need to surgery and bleeding. Beam penumbra phenomenon leads to irradiation outside the field and normal tissues. Therefore, considering it is momentous to attain the acceptable treatment plan. Materials and Methods: In this study, Gamma Knife unit was modeled using EGSnrc/BEAMnrc Monte Carlo code. SDD (Source to Diaphragm Distance) parameter that is one of the affecting factors on physical penumbra width was studied. For this purpose, SDD was increased for 4, 8, 14 and 18 mm collimator sizes in five steps and each step as much as one centimeter. Single beam profiles were calculated using EGSnrc/DOSXYZnrc code at isocentre depth in a cubic Plexiglas phantom. MATLAB and EXCEL software were used to plot profiles and measure physical penumbra width . Results: Based on the results, physical penumbra width (90%-50%) does not show a regular trend with increasing SDD. This may be attributed to scatter radiation which is due to the low distance between the Gamma Knife collimator end and phantom surface. Best results were observed for 4 and 8 mm collimators in 1 cm increase in which penumbra width decreased from 0.785 and 0.790 mm to 0.749 and 0.736 mm for 4 and 8 mm collimator sizes, respectively. Conclusion: It is recommended to increase SDD of Gamma Knife 4C around 1 centimeter to reduce penumbra width for small tumor sizes located near the critical nerves.
کلیدواژههای انگلیسی مقاله
Gamma Knife Monte Carlo code SDD, Physical penumbra
نویسندگان مقاله
| Atefeh Mahmoudi
Master Student, Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
| Ghazale Geraily
Assistant Professor, Medical Physics and Biomedical Engineering, Department, Tehran University of Medical Sciences, Tehran, Iran
| Alireza Shirazi
Full Professor, Medical Physics and Biomedical Engineering, Department, Tehran University of Medical Sciences, Tehran, Iran
| Masoume Bakhshi
Master Student, Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_13027.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات