این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 26 مهر 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۹، شماره ۲، صفحات ۱۲۷-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Effect of Changing Cross Head Speed on Shear Bond Strength of Orthodontic Brackets and Mode of Adhesive Failure
چکیده انگلیسی مقاله
Statement of Problem: In most shear bond strength (SBS) studies, different cross head speeds have been used.The effect of different speeds on the shear bond strength has been studied in very limited researches. Purpose: The aim of this study was to evaluate the influence of changing cross head speed of testing machine on the shear bond strength and failure mode of orthodontic adhesive (Transbond XT) in bracket bonding. Materials and Method: For this experimental study, 175 human premolars with intact enamels were divided into seven equal groups of 25. After surface preparation, brackets were bonded to teeth using transbond XT adhesive. For debonding process various cross head speeds of 0.5, 1, 2.5, 5, 7.5, 10, 25 mm/min were applied. Shear bond strength and Adhesive Remnant Index (ARI) were recorded for different groups. One way ANOVA and Tukey tests were used for bond strength comparison. Data on shear bond strength evaluations and modes of bond failure were analyzed using Kruskal- wallis and spearman tests. Results: The means of shear bond strength for the applied 0.5, 1, 2.5, 5, 7.5, 10 and 25 mm/min cross- head speeds were 16.39, 14.37, 13.30, 14.12, 13.32, 16.58, and 13.83 respectively. Shear bond strengths in groups receiving 0.5, 10 mm/min cross head speeds, were significantly greater than other groups. No significant differences were obtained between these two speeds, as well as, between 1, 2.5, 5, 7.5, 25 mm/min speeds, but there were significant differences in the shear bond strengths between the two groups with the cross head speeds of 0.5, 10, and 1, 2.5, 5, 7.5, 25 mm/min. Considering the ARI, no differences were found between the groups. Also, there was no relation between ARI and bond strength in groups with different cross head speeds, except in 5mm/min. Conclusion: Cross head speed of Instron is an effective factor on the SBS of the adhesives, but it does not have significant effect on the failure mode of bonding materials.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
hr پاکشیر | hr pakshir
associate professor, department of orthodontics, school of dentistry, member of orthodontic research center, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
z farbodan | z farbodan
orthodontist, private practice
z هدایتی | z hedayati
associate professor, department of orthodontics, school of dentistry, member of orthodontic research center, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
نشانی اینترنتی
http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/334
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات