این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
شنبه 2 خرداد 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۹، شماره ۳، صفحات ۲۸۵-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Assessment of Correlation between Dye Penetration and Electrochemical Methods on Apical Microleakage
چکیده انگلیسی مقاله
Statement of Problem: The most important failure factor of root canal treatment is lack of proper seal of root canal, which leads to leakage and penetration of microorganism in to the canals. Different methods have been used to determine the apical seal. Purpose: This study was aimed at comparing the apical leakage using dye penetration and electrochemical methods successively used on the same teeth. Materials and Method: For this experimental study, 31 freshly extracted anterior single root human teeth with straight root canals were selected. The specimens were randomly divided into experimental, positive and negative control groups. Root canals of the experimental and negative group were filled, and positive group were left unfilled. The external surface of each tooth was coated with two layers of the nail polisher, except for the apical 2mm and coronal portion. Leakage of the teeth were measured using electrochemical me thud. Two copper wires were used as electrodes and normal saline solution was used as electrolyte. Then coronal portions of the roots were filled using ZOE cement and coated with two layers of the nail polisher. The teeth were immersed in 2% basic Fuchsine for 48 hours and were washed in tap water. The roots were then split longitudinally and dye penetration was assessed for each tooth. The data were analyzed using t-test and Pierson correlation coefficient test. Results: The obtained results in electrochemical methods varied from 3.1 to 54.7 Micro amper, while in dye penetration method the observed leakage was 2.5 to 6.8 mm. The coefficient correlation between the two methods was found to be 0.204 (r = 0.204, p 0.5). Conclusion: Since no correlation was found among the results obtained with the two methods, it is concluded that, for assessment of the marginal leakage of dental materials, various methods should be considered.
کلیدواژههای انگلیسی مقاله
Tooth Apex, Dye, Electrochemical, Microleakage
نویسندگان مقاله
j مدرسی | j modaresi
dept. of endodontics, school of dentistry, yazd university of medical sciences, yazd, iran
سازمان اصلی تایید شده
: دانشگاه یزد (Yazd university)
z بحرالعلومی | z bahrololoomi
dept. of pediatric, school of dentistry, yazd university of medical sciences, yazd, iran
سازمان اصلی تایید شده
: دانشگاه یزد (Yazd university)
منصور رضایی | m rezaei
dentist, private practice, yazd, iran
نشانی اینترنتی
http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/327
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات