این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 24 مهر 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۹، شماره ۴، صفحات ۳۳۸-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Accuracy and Dimensional Stability of two Polysiloxane Putty- wash Impression Techniques
چکیده انگلیسی مقاله
Statement of problem: The accuracy and dimensional stability of dental impression materials and technique is an important factor in the accuracy and fitness of the final restoration. Condensation- reaction polysilicone impression material has adequate accuracy and is the most commonly used material in fixed prosthodontic restorations with putty- wash technique. There are different considerations and controversies in the literature about the effect of impression technique on the accuracy of restoration. Purpose: The aim of this study was to compare the accuracy and dimensional stability of two polysiloxane putty- wash impression techniques with and without spacer. Materials and Method: A laboratory model with two metallic dies was used. In one of the dies a horizontal notch was applied as an undercut. Ten impressions were made without spacer and another ten with spacer. Twenty stone models were made from both techniques. Dimensions of the stone models were measured and comparison was made with the laboratory model dimensions. The results were analyzed using T- test. Results: The results showed that the height of the dies without undercut was decreased in both groups, being significant in non- spacer technique ( p < 0.001). The distance between the two dies increased in both techniques. The difference was significant in technique without spacer ( p < 0.002). The height of the dies above the undercut increased and in both techniques they proved to be statistically significant (without spacer p < 0.003 and with spacer p < 0.001). Conclusion: The polysiloxane putty- wash impression technique with spacer is more accurate for fabricating the stone die.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
p امینی | p amini
dept. of prosthodontics, school of dentistry, kerman university of medical sciences, kerman, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی کرمان (Kerman university of medical sciences)
محمد رحیمی | m rahimi
dentist
نشانی اینترنتی
http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/307
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات