این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Dentistry, Shiraz University of Medical Sciences، جلد ۱۴، شماره ۳، صفحات ۱۱۸-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques
چکیده انگلیسی مقاله Statement of Problem: Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. Purpose: This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Materials and Method: Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student’s t - test was used for statistical analysis (α=0.05). Results: The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student’s t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group ( p < 0.001). Conclusion: Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله m وجدانی | m vojdani
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

k ترابی | k torabi
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

e فرجود | e farjood
postgraduate student, dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)

aar خالدی | aar khaledi
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)


نشانی اینترنتی http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/7
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات