این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 شهریور 1404
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۱۴، شماره ۳، صفحات ۱۱۸-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparison the Marginal and Internal Fit of Metal Copings Cast from Wax Patterns Fabricated by CAD/CAM and Conventional Wax up Techniques
چکیده انگلیسی مقاله
Statement of Problem: Metal-ceramic crowns are most commonly used as the complete coverage restorations in clinical daily use. Disadvantages of conventional hand-made wax-patterns introduce some alternative ways by means of CAD/CAM technologies. Purpose: This study compares the marginal and internal fit of copings cast from CAD/CAM and conventional fabricated wax-patterns. Materials and Method: Twenty-four standardized brass dies were prepared and randomly divided into 2 groups according to the wax-patterns fabrication method (CAD/CAM technique and conventional method) (n=12). All the wax-patterns were fabricated in a standard fashion by means of contour, thickness and internal relief (M1-M12: representative of CAD/CAM group, C1-C12: representative of conventional group). CAD/CAM milling machine (Cori TEC 340i; imes-icore GmbH, Eiterfeld, Germany) was used to fabricate the CAD/CAM group wax-patterns. The copings cast from 24 wax-patterns were cemented to the corresponding dies. For all the coping-die assemblies cross-sectional technique was used to evaluate the marginal and internal fit at 15 points. The Student’s t - test was used for statistical analysis (α=0.05). Results: The overall mean (SD) for absolute marginal discrepancy (AMD) was 254.46 (25.10) um for CAD/CAM group and 88.08(10.67) um for conventional group (control). The overall mean of internal gap total (IGT) was 110.77(5.92) um for CAD/CAM group and 76.90 (10.17) um for conventional group. The Student’s t-test revealed significant differences between 2 groups. Marginal and internal gaps were found to be significantly higher at all measured areas in CAD/CAM group than conventional group ( p < 0.001). Conclusion: Within limitations of this study, conventional method of wax-pattern fabrication produced copings with significantly better marginal and internal fit than CAD/CAM (machine-milled) technique. All the factors for 2 groups were standardized except wax pattern fabrication technique, therefore, only the conventional group results in copings with clinically acceptable margins of less than 120um.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
m وجدانی | m vojdani
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
k ترابی | k torabi
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
e فرجود | e farjood
postgraduate student, dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
aar خالدی | aar khaledi
dept. of prosthodontics, school of dentistry, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
نشانی اینترنتی
http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/7
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات