این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 23 تیر 1405
Journal of Dentistry, Shiraz University of Medical Sciences
، جلد ۱۶، شماره ۲، صفحات ۱۲۱-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Retention of two Different Cast Post-Core Systems and Fracture Resistance of the Restored Teeth
چکیده انگلیسی مقاله
Statement of the Problem: The survival of pulpless teeth restored with different post and core systems is still a controversial issue. Purpose: This study compared the retention of two different post and core systems and also the fracture resistance of teeth restored with these systems. Material and Method: Eighty endodontically treated maxillary central incisors were sectioned perpendicular to the long axis at a point 2mm incisal to the cemento-enamel junction (CEJ) and then the root canals were obturated. The restored teeth were randomly divided into two equal groups of 40. One group was restored with Nickel-Chromium (Ni-Cr) post and core system and the other group with Non-Precious Gold alloy (NPG) system. For evaluation of fracture resistance of the restored teeth, the specimens (n=20 per each group) were mounted in acrylic resin blocks and a layer of polyvinyl siloxane was applied to cover the roots. Loads were applied at an angle of 45 degrees to the long axis of the teeth and measured with a universal testing machine. The axial retention values of the studied groups (no=20) were measured on an Instron testing machine at a crosshead speed of 0.5 mm/min. Statistical analyses were performed using SPSS version 19.00 and student’s t-test (α=0.05). Results: Although retention failure load for Ni-Cr system was lower than NPG system, there was no significant difference between the two systems ( p = 0.7). However, fracture resistance of the teeth restored with Ni-Cr post and core system was significantly higher than NPG group ( p = 0.000). Conclusion: There was no significant difference between the retention of the studied post and core systems. Although significantly higher fracture thresholds were recorded for Ni-Cr post and core group, the failure loads of both systems may rarely occur clinically.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
امیر علی رضا خالدی | amir ali reza khaledi
dept. of prosthodontic, school of dentistry, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
شکوفه شیخیان | shekufe sheykhian
students’ research committee, school of dentistry, international branch, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
آرش خدایی | arash khodaei
students’ research committee, school of dentistry, international branch, shiraz university of medical sciences, shiraz, iran.
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی شیراز (Shiraz university of medical sciences)
نشانی اینترنتی
http://dentjods.sums.ac.ir/index.php/JDSUMS/article/view/1092
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Article
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات