عنوان انگلیسی Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)
چکیده انگلیسی مقاله Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether increasing the FFD from 100 to 130 cm is equally effective for other common radiological procedures and performing a literature review of published studies to address the feasibility and probable limitations against implementing this optimization tool in clinical practice. Materials and Methods Radiographic examination of the pelvis (AP view), abdomen (AP view), skull (AP and lateral view), and spine (AP and lateral view), were taken of pediatric patients. The radiation dose and image quality of a radiological procedure is measured in FFD of 100 cm (reference FFD) and 130 cm (increased FFD). The thermo-luminescent dosimeters (TLD) were used for radiation dose measurements and visual grading analysis (VGA) for image quality assessments. Results: Statistically significant reduction in the ESD ranged from 21.91% for the lateral skull projection to 35.24% for the lateral spine projection was obtained, when the FFD was increased from 100 to 130 cm (P< 0.05). Optimum image quality was obtained for all projections in both FFDs. VGA of the resultant images demonstrated a statistically non-significant minor increase in image quality of lateral skull and spine projections, when increasing from 100 to 130 cm FFDs (P>0.05). Conclusion Increasing the FFD from 100 to 130 cm has significantly reduced radiation exposure without affecting on image quality. Our findings are commensurate with the literatures and emphasized that radiographers should learn to use of an updated reference FFD of 130 cm in clinical practice.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله وحید کرمی | vahid karami
department of medical physics, school of medicine, ahvaz jundishapur university of medical sciences, ahvaz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی جندی شاپور اهواز (Ahvaz jundishapur university of medical sciences)

منصور ذبیح زاده | mansour zabihzadeh
department of clinical oncology, golestan hospital, ahvaz jundishapur university of medical sciences, ahvaz, iran and department of oral and maxillofacial radiology, school of dentistry, ahvaz jundishapur university of medical sciences, ahvaz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی جندی شاپور اهواز (Ahvaz jundishapur university of medical sciences)

نسیم شمس | nasim shams
department of oral and maxillofacial radiology, school of dentistry, ahvaz jundishapur university of medical sciences, ahvaz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی جندی شاپور اهواز (Ahvaz jundishapur university of medical sciences)

عبدالرضا گیلاوند | abdolreza gilavand
employed experts on faculty appointments, ahvaz jundishapur university of medical sciences, ahvaz, iran.

سازمان اصلی تایید شده: دانشگاه علوم پزشکی جندی شاپور اهواز (Ahvaz jundishapur university of medical sciences)


نشانی اینترنتی http://ijp.mums.ac.ir/article_8333.html
فایل مقاله دریافت فایل مقاله
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات