Assessment of Dosimetric Accuracy and Plan Quality in Prostate SBRT Using RapidArc with Analysis of Varian MLC Parameters
چکیده انگلیسی مقاله
Introduction: Prostate cancer is a highly prevalent malignancy worldwide. Advances in radiotherapy, particularly SBRT, have enabled ultra-hypofractionated treatments that improve tumor control while reducing treatment time. This study evaluates the dosimetric accuracy and plan quality of prostate SBRT delivered using RapidArc technology on a Varian Millennium Multi Leaf Collimator (MLC) system.Material and Methods: Twenty-four patients with localized prostate adenocarcinoma received SBRT with a prescribed dose of 36.25 Gy in five fractions. Treatment planning was performed using Eclipse v15.6 with the Acuros XB algorithm, employing three 6 MV Flattening Filter Free (FFF) arcs. Planning Target Volume (PTV) coverage, Organs At Risk (OAR) doses, Paddick Conformity Index (PCI), Gradient Index (GI), and Monitor Units (MU) were analyzed. MLC performance was assessed using trajectory log files to evaluate leaf speed and positional accuracy. Pre-treatment Quality Assurance (QA) was conducted using Electronic Portal Imaging Device (EPID)-based gamma analysis.Results: The mean PTV D95 was 35.80 ± 0.46 Gy, with Dmax and Dmean of 39.80 ± 1.05 Gy and 37.10 ± 0.40 Gy, respectively. V95% averaged 99.13 ± 1.14%, confirming adequate coverage. The bladder and rectum Dmax slightly exceeded constraints, while all other OAR objectives were met. Gamma pass rates exceeded 99.6% for the 2%/2mm criterion. MLC leaf speed remained below 2.5 cm/s, ensuring delivery accuracy.Conclusion: RapidArc-based prostate SBRT demonstrated high conformity, efficient delivery, and acceptable OAR sparing. Intra-fraction CBCT improved setup accuracy, and MLC log-file analysis confirmed mechanical precision, supporting the feasibility of this approach for localized prostate cancer.
کلیدواژههای انگلیسی مقاله
Prostatic Neoplasms Radiotherapy Intensity, Modulated Radiotherapy Dosage Delivery of Health Care
نویسندگان مقاله
| Ajithkumar M
Department of Radiotherapy, Meherbai Tata Memorial Hospital, Jamshedpur
| Subhankar Show
Department of Radiotherapy, Meherbai Tata Memorial Hospital, Jamshedpur
| Aaditya Prakash
Department of Radiotherapy,Tata MainHospital, Jamshedpur
نشانی اینترنتی
https://ijmp.mums.ac.ir/article_27215.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات