این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Reproduction and Infertility، جلد ۲۶، شماره ۴، صفحات ۲۴۸-۲۵۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی The Effect of Fetal Intrauterine Blood Transfusion on Ductal Arterial Blood Flow Velocity and Cardiac Output Changes in Fetuses with Rhesus Alloimmunization-Related Anemia
چکیده انگلیسی مقاله

Background: Echocardiographic indicators may be useful as an alternative method to determine the appropriate time for intervention, especially when Doppler assessment of the middle cerebral artery peak systolic velocity (MCA-PSV) is inconclusive. In this study, arterial duct blood flow and cardiac output of fetuses with Rh alloimmunization-related anemia were compared before and after intrauterine transfusion (IUT).
Methods: Fifty intrauterine blood transfusions were performed on anemic fetuses in this study. All cases were attributed to Rh alloimmunization, detected with MCA-PSV Doppler ultrasound imaging assessments. They all underwent intrauterine blood transfusion and echocardiographic assessments a day before and 24 hr after the procedure. The measured cardiac indices included the velocity time integral (VTI) of the aortic and pulmonary valves, the ductus arteriosus acceleration-to-ejection time (AT/ET) ratio, and the MCA-PSV. Analyses were performed in SPSS v24 (p<0.05) using paired t-tests for mean differences and Pearson’s correlation for associations between continuous variables.
Results: Aortic and pulmonary valve VTI, MCA-PSV, and ductus arteriosus AT/ET ratio significantly decreased after intrauterine blood transfusion (p<0.001). The aortic valve VTI and ductus arteriosus accurately detected anemia, with areas under the receiver operating characteristic (ROC) curve of 99.9% and 98.9%, respectively. 
Conclusion: All the measured parameters showed significant changes after intrauterine blood transfusion. Aortic valve VTI and ductus arteriosus AT/ET ratio seem to have the highest accuracy in detecting anemia. Echocardiographic assessment can be beneficial in defining the appropriate time for intrauterine blood transfusion in cases where MCA-PSV is inefficient.

کلیدواژه‌های انگلیسی مقاله Ductus arteriosus, Echocardiography, Intrauterine blood transfusion

نویسندگان مقاله | Behrokh Sahebdel
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Mohammad Nasir Hematian
Department of Perinatology and Fetal Cardiology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Zohreh Heidary
Vali-E-Asr Reproductive Health Research Center, Family Health Research Institute, Tehran University of Medical Sciences, Tehran, Iran


| Fatemeh Rahimi-Sharbaf
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Fatemeh Golshahi
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Mahboobeh Shirazi
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Nafiseh Saedi
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Faezeh Mahdavi Omran
Department of Medical Education, Faculty of Medicine, Babol University of medical sciences, Babol, Iran


| Zahra Moradi
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran


| Sodabeh Rezaei
Department of Obstetrics and Gynecology, Yas Hospital complex, Tehran University of Medical Sciences, Tehran, Iran



نشانی اینترنتی https://www.jri.ir/article/140284
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات