|
Iranian Journal of Chemistry and Chemical Engineering، جلد ۴۳، شماره ۹، صفحات ۳۱۶۸-۳۱۸۰
|
|
|
عنوان فارسی |
|
|
چکیده فارسی مقاله |
|
|
کلیدواژههای فارسی مقاله |
|
|
عنوان انگلیسی |
Fabrication and Characterization of Dental Implant Technology Utilizing Hydroxyapatite (HA) Nanoparticles Composed with Ceramics via Electrophoretic Deposition Technique on Stainless Steel |
|
چکیده انگلیسی مقاله |
The field of restorative dentistry has witnessed a significant transformation by introducing dental implant technology, which offers a dependable approach to replacing absent teeth. This research aims to investigate the manufacturing and evaluation processes involved in dental implants made from stainless steel 316L as the primary material, with the addition of a hydroxyapatite (HA) coating. The objective is to enhance osseointegration, reduce implant failure rates, and improve inflammation management. Advanced manufacturing techniques were employed to fabricate stainless steel 316L implants, followed by a uniform HA coating deposition through the ElectroPhoretic Deposition (EPD) technique. A comprehensive evaluation was conducted, including mechanical tests, biocompatibility studies, histological analysis, and radiographic evaluations, to assess implant properties, osseointegration, and inflammation management. Early results indicate promising outcomes for dental implant applications utilizing stainless steel 316L with a HA coating. Stainless steel 316L exhibits excellent mechanical properties, while the HA coating enhances bioactivity and osteoconductivity. The coated implants demonstrate improved osseointegration and a reduced risk of implant failure. Furthermore, the incorporation of HA shows potential for effective inflammation management due to its anti-inflammatory properties. This study shows the potential of dental implants fabricated with stainless steel 316L and a HA coating. The synergistic effects of the material and coating hold promise for enhanced implant performance, improved osseointegration, and effective inflammation management. Further research and clinical studies are necessary to validate these findings and optimize the design and manufacturing processes for widespread implementation in dental implantology. |
|
کلیدواژههای انگلیسی مقاله |
Dental implants,Stainless steel 316L,Hydroxyapatite coating,Osseointegration,Implant failure,Inflammation management |
|
نویسندگان مقاله |
Weili Wang | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Lei Li | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Ying Chang | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Zhuojue Liu | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Bin Xuan | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Wenpeng Yang | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
Xingyu Fan | Department of Stomatology, Aerospace Center Hospital, Beijing, 100049, P.R. CHINA
|
|
نشانی اینترنتی |
https://ijcce.ac.ir/article_715480_52d32790b105e2e8e7a9ee182e1438ad.pdf |
فایل مقاله |
فایلی برای مقاله ذخیره نشده است |
کد مقاله (doi) |
|
زبان مقاله منتشر شده |
en |
موضوعات مقاله منتشر شده |
|
نوع مقاله منتشر شده |
|
|
|
برگشت به:
صفحه اول پایگاه |
نسخه مرتبط |
نشریه مرتبط |
فهرست نشریات
|