Bulletin of Emergency and Trauma، جلد ۱۲، شماره ۳، صفحات ۱۱۷-۱۲۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Preventing Proximal Radio-Ulnar Joint Screw Penetration during Coronoid Fracture Fixation: A 3D-Digital Modeling and Cadaver Study
چکیده انگلیسی مقاله Objective: Intra-articular screw penetration is a probable complication of coronoid fracture fixation. The
present study aimed to determine the best radiography technique for visualizing the proximal radioulnar joint
(PRUJ) space. Moreover, it aimed to determine the safe angle and length of the screw to avoid PRUJ penetration
during coronoid fracture fixation.
Methods: The Mimics software was used to construct a three-dimensional model of a healthy man’s forearm
from a computer tomography scan. It was analyzed using the Solidworks software to determine the X-ray angle
that clearly showed the PRUJ space to detect penetration of screws from the coronoid process into the PRUJ
and determine the maximum screw angle and length that could be used without intra-articular penetration. To
verify these findings, a cadaveric study combined with radiographs was conducted.
Results: To visualize PRUJ space, the optimal X-ray angle was 13º lateral to the perpendicular line when the
forearm was positioned at full supination. If the coronoid process was segmented into zones 1 (closest to the
radioulnar joint) to 4 (farthest from the joint), the screw could only be inserted at a right angle in zone 1. In zones
2, 3, and 4, inclination angles less than 15, 35, and 60 would prevent intra-articular penetration, respectively.
Conclusions: The X-rays could visualize the PRUJ space with an anteroposterior radiograph at an angle of
13º ulnar deviation from the perpendicular plane. During coronoid process fracture fixation, shorter screws
with less lateral inclination were safer when inserting screws in the zones of the coronoid process adjacent to
the PRUJ.
کلیدواژه‌های انگلیسی مقاله screw placement,coronoid process,Cadaver,Elbow,Computer simulation

نویسندگان مقاله Armin Akbarzadeh |
Department of Orthopedic surgery, Shiraz University of Medical Sciences, Shiraz, Iran.

Hamid Namazi |
Bone and Joint Diseases Research Center, Shiraz University of Medical Sciences, Shiraz, Iran

Ayub Gharebeigi Tavabeh |
Department of Orthopedic Surgery, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran

Seyyed Arash Haghpanah |
Department of Solid Mechanics Engineering, School of Mechanical Engineering, Shiraz University, Shiraz, Iran

Doroudchi Alireza |
Legal Medicine Research Center, Iranian National Legal Medicine Organization, Tehran, Iran


نشانی اینترنتی https://beat.sums.ac.ir/article_50343_a752e73dc940fc9b27e5ce0d0a985fb8.pdf