این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Endodontic Journal، جلد ۱۲، شماره ۲، صفحات ۱۷۹-۱۸۴

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Effect of Field Of View on Detection of External Root Resorption in Cone-Beam Computed Tomography
چکیده انگلیسی مقاله Introduction: Conventional methods for diagnosis of external root resorption (ERR) are based on clinical findings and x-ray observations which are not appropriate for early diagnosis. The present study assessed the effect of different sizes and field of views (FOVs) in the diagnosis of simulated external root resorption by cone-beam computed tomography (CBCT). Methods and Materials: In this diagnostic in vitro trial, 100 human extracted mandibular central incisors were collected and marked in 3 apical, middle and coronal areas. Cavities with different sizes were created in buccal and lingual surfaces of each area. Following this procedure, CBCT images were taken in 2 different 6 × 6 cm and 12 × 8 cm FOVs with the same voxel size of 0.2 mm. Absence or presence of cavities in CBCT images were assigned by 3 radiologists and compared with gold standard results which were obtained by measurement of the size of cavities using a digital caliper. Sensitivity and specificity values, positive predictive value (PPV) and negative predictive value (NPV), A Z value and Kappa values were calculated and reported. Results: Amounts of sensitivity in 6 × 6 cm FOV with voxel size of 0.2 mm for small, medium and large cavities were 95.93%, 96.03% and 97.1%, respectively. Amounts of sensitivity in 12 × 8cm FOV with the same voxel size for small, medium and large cavities were noted as 94.4%, 96.03% and 98.5%, respectively. However, specificity in FOV of 6 × 6 cm and FOV of 12 × 8 cm was calculated as 93.03% and 90.83%, respectively. Conclusion: Both used FOVs show nearly same performances in the case of detection of ERR; therefore, smaller FOV should be preferably used for detection of ERR in order to decrease the amount of imposed radiation dose given to patients.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله یاسر صافی | yaser safi


سحر قایدشرف | sahar ghaedsharaf


علیرضا عزیز | alireza aziz


سپنتا حسین پور | sepanta hosseinpour


حامد مرتضوی | hamed mortazavi



نشانی اینترنتی http://journals.sbmu.ac.ir/iej/article/view/13242
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/109/article-109-326836.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Article
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات