Analytical and Bioanalytical Electrochemistry
، جلد ۱۴، شماره ۴، صفحات ۳۸۵-۴۰۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Electrochemical-Sensor Behavior for Determination of Low Urea Concentration using Graphite-TiO2 Composites Immobilized in a Glass Tube
چکیده انگلیسی مقاله
A high urea compound in human blood is indicated for kidney disease, urinary tract stones, and even bladder tumors. It is necessary to take several preventive measures, starting with detecting the urea compound. This study presents the preparation of a working electrode based on graphite-TiO
2
(G/TiO
2
) composites immobilized into a glass tube for sensing urea compound under an electrochemical system. The G/TiO
2
composites were successfully synthesized through a physical mixing method and then immobilized into a glass tube for fabricating a working electrode to sense the urea compound under the cyclic voltammetry (CV) technique. The material characterization results show that the nano-TiO
2
powder is composed of irregular polycrystalline and amorphous, revealing a broad pattern with low intensity. However, the effect of amorphous materials on the expansion of the nano-sized XRD TiO
2
pattern is negligible. In addition, the morphological analysis of graphite has a very tight layer of flakes with a smooth and uniform surface. At the same time, the G/TiO
2
composites are also granule-shaped that attached to the graphite surface, identified to cover part of the graphite surface. Under the electrochemical performance test, the excellent composition of TiO
2
modifier is 0.5 g mixed into graphite to sense urea compound by using CV technique under a scan rate of 0.5 V.s
-1
with 0.1M K
3
[Fe(CN)
6
] (+0.1M NaNO
3
) electrolyte solution. We obtain a standard deviation of 0.361403514 and a detection limit of 0.005976905 mg.L
-1
with RSDr and PRSDr values of 5.51% and 3.13%, respectively. The performance of the electrodes over 25 days showed a significant effect on stability over 10 days.
کلیدواژههای انگلیسی مقاله
sensor,urea,Electrode,material,Diseases
نویسندگان مقاله
Dwiprayogo Wibowo |
Department of Environmental Engineering, Faculty of Engineering, Universitas Muhammadiyah Kendari, Kendari 93117 – Southeast Sulawesi, Indonesia
Wa Ode Suci Indah Sari |
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Kendari 93231 – Southeast Sulawesi, Indonesia
Anwar Said |
Fishery Products Technology, Faculty of Fisheries and Marine Science, Universitas Muhammadiyah Kendari, Kendari 93117 – Southeast Sulawesi, Indonesia
Faizal Mustapa |
Doctoral student of Agriculture, Department of Water Resources, Universitas Halu Oleo, Kendari 93231 – Southeast Sulawesi, Indonesia
Bernadetha Susianti |
PT. Jara Silica, Sugihwaras, Jenu, Tuban 62352, East Java – Indonesia
Maulidiyah Maulidiyah |
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Kendari 93231 – Southeast Sulawesi, Indonesia
Muhammad Nurdin |
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Kendari 93231 – Southeast Sulawesi, Indonesia
نشانی اینترنتی
https://www.abechem.com/article_252040_cdd6f0155294f7650946a1627aa58ed1.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات