این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 25 مهر 1404
Tanaffos
، جلد ۱۳، شماره ۱، صفحات ۲۰-۲۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Bronchodilator Response of FEV6 and FEV3 as Surrogates of Forced Vital Capacity
چکیده انگلیسی مقاله
Background: Spirometry as a non-invasive and inexpensive test is widely used for occupational health evaluations. Bronchodilator test is used for the assessment of airflow limitation and increase in forced expiratory volume in 1 second (FEV1) or forced vital capacity (FVC) is considered as a positive response. This study was performed to assess the response of forced expiratory volume in 6 seconds (FEV6), forced expiratory volume in 3 seconds (FEV3), and forced expiratory time (FET) to bronchodilator administration. Materials and Methods: In this cross-sectional study, the response of FEV3, FEV6, FEV1/FEV3, FEV1/FEV6 and FET to bronchodilator administration was assessed in subjects referred to Yazd occupational medicine clinic regardless of their diagnosis. The average increase in spirometric parameters (i.e. FVC, FEV1, FEV1/FVC, FEV3, FEV6, FEV1/FEV3, FEV1/FEV6 and FET) was measured. The difference between baseline and post-bronchodilator spirometries was assessed by calculating absolute change and change from baseline as well. Data analysis was done by Student’s t test, chi square test and Pearson's correlation test. Results: Totally 104 subjects were entered in the study. FEV1 showed the highest response to bronchodilator. FVC response to bronchodilator was correlated with FET, but such correlation was not observed for FEV6 and FEV3. The mean increase in FEV6, FEV3, and FET after bronchodilator administration was 50.90 ml (2.23%), 110.51 ml (3.08%) and -1.85 s, respectively. Conclusion: FVE6 can be used as a substitute for FVC for the assessment of bronchodilator response without the need for FET adjustment.
کلیدواژههای انگلیسی مقاله
Spirometry,Bronchodilator test,FVC,FEV6,FEV1,FET
نویسندگان مقاله
Amir Houshang Mehrparvar |
Occupational Medicine Department and Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran,
Seyed Jalil Mirmohammadi |
Occupational Medicine Department and Industrial Diseases Research Center, Shahid Sadoughi University of Medical Sciences, Yazd, Iran,
Seyed Hesam Hashemi |
Occupational Medicine Department, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
Mehrdad Mostaghaci |
Occupational Medicine Department, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
Hadi Eshaghi Sani |
Occupational Medicine Department, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
Sara Safaie |
Occupational Medicine Department, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
نشانی اینترنتی
https://www.tanaffosjournal.ir/article_240982_72324bcc0575b692206878ea7e69f347.pdf
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات