Iranian Journal of Neonatology، جلد ۷، شماره ۱، صفحات ۴۱-۴۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
چکیده انگلیسی مقاله Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC) curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD) blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.
کلیدواژه‌های انگلیسی مقاله Glucometer, Neonatal hypoglycemia, Screening

نویسندگان مقاله محمد ترکمان | mohammad torkaman
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)

غلامرضا باقری | gholamreza bagheri
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)

احمد احمدی | ahmad ahmadi
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)

امین صبوری | amin saburi
birjand atherosclerosis and coronary artery research center, birjand university of medical sciences, birjand, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی بیرجند (Birjand university of medical sciences)


نشانی اینترنتی http://ijn.mums.ac.ir/article_6664.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده تحقیقی اصیل
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات